Listwa zaciskowa falownika Omron G7
Listwa zaciskowa falownika Omron G7 modele do 15kW
Listwa zaciskowa falownika Omron G7 modele do 15kW
Voltage | 200 V | 400 V | ||||
Model CIMR-G7CD | 20P4 to 2015 | 2018, 2022 | 2030 to 2110 | 40P4 to 4015 | 4018 to 4045 | 4055 to 4300 |
Max. applicable motor output | 0.4 to 15 kW | 18.5 to 22 kW | 30 to 110 kW | 0.4 to 15 kW | 18.5 to 45 kW | 55 to 300 kW |
R/L1 | Main circuit input power supply | Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment | Main circuit input power supply | Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment | ||
S/L2 | ||||||
T/L3 | ||||||
R1/L11 | - | --- | ||||
S1/L21 | ||||||
T1/L31 | ||||||
U/T1 | Inverter output | Inverter output | ||||
V/T2 | ||||||
W/T3 | ||||||
B1 | Braking resistor unit | Braking resistor unit | ||||
B2 |
Type | No. | Signal name | Function | Signal level |
Sequence input | S1 | Forward run/stop signal | Forward run at "closed", stop at "open" | Photo-coupler input +24 VDC 8 mA isolation |
S2 | Reverse run/stop signal | Reverse run at "closed", stop at "open" | ||
S3 | Multi-function input selection 1 | Factory setting: external fault at "closed" | ||
S4 | Multi-function input selection 2 | Factory setting: fault reset at "closed" | ||
S5 | Multi-function input selection 3 | Factory setting: multi-step speed setting 1 is valid at "closed" | ||
S6 | Multi-function input selection 4 | Factory setting: multi-step speed setting 2 is valid at "closed" | ||
S7 | Multi-function input selection 5 | Factory setting: JOG run at "closed" | ||
S8 | Multi-function input selection 6 | Factory setting: external baseblock at "closed" | ||
S9 | Multi-function input selection 7 | Factory setting: multi-step speed setting 3 is valid at "closed" | ||
S10 | Multi-function input selection 8 | Factory setting: multi-step speed setting 4 is valid at "closed" | ||
S11 | Multi-function input selection 9 | Factory setting: accel/decel time setting 1 is valid at "closed" | ||
S12 | Multi-function input selection 10 | Factory setting: emergency stop (NO contact) is valid at "closed" | ||
SC | Sequence control input common | - | ||
Analog input | +V | +15 V power supply output | For analog reference +15 V power supply | +15 V (allowable current 20 mA max.) |
-V | -15 V power supply output | For analog reference -15 V power supply | -15 V (allowable current 20 mA max.) | |
A1 | Master speed frequency reference | -10 to +10 V/ -100 to +100%, 0 to +10 V/ 100% | -10 to +10 V, 0 to +10V (input impedance 20 k) | |
A2 | Multi-function analog input | 4 to 20 mA/100%, -10 to +10 V/ -100 to +100%, 0 to +10 V/ 100% Factory setting: added to the terminal A1 (H3-09=0) | 4 to 20 mA (input impedance 250 £2) | |
A3 | Master speed frequency reference | -10 to +10 V/ -100 to +100%, 0 to +10 V/ 100% Factory setting: preset frequency reference | 0 to +10 V (input impedance 20 k£) | |
AC | Analog common | 0 V | - | |
E(G) | Connection to shield wire and option ground wire | - | - | |
Photo-coupler output | P1 | Multi-function PHC output 1 | Factory setting: zero speed signal "Closed" at or below zero speed level (b2-01) | +48 VDC 50 mA or less |
P2 | Multi-function PHC output 2 | Factory setting: frequency agreement "Closed" within ±2Hz of setting frequency | ||
PC | Photo-coupler output common | - | ||
P3 | Multi-function PHC output 3 | Factory setting: ready to operate (READY). | ||
C3 | ||||
P4 | Multi-function PHC output 4 | Factory setting: frequency (FOUT) detection 2 | ||
C4 | ||||
Relay output | MA | Fault output (NO contact) | Fault at "closed" between terminals MA and MC | Dry contact, contact capacity 250 VAC 1 A or less 30 VDC 1 A or less |
MB | Fault output (NC contact) | Fault at "open" between terminals MB and MC | ||
MC | Rely contact output common | - | ||
M1 | Multi-function contact output (NO contact) | Factory setting: run signal Running at "closed" between terminals M1 and M2 | ||
M2 | ||||
Analog monitor output | FM | Multi-function analog monitor 1 | Factory setting: output frequency 0 to 10 V/100% freq. | 0 to +10 VDC ±5% 2 mA or less |
AM | Multi-function analog monitor 2 | Factory setting: current monitor 5 V / inverter rated current | ||
AC | Analog common | - | ||
Pulse I/O | RP | Multi-function pulse input | Factory setting: frequency reference input (H6-01=0) | 0 to 32 kHz (3 k£2) |
MP | Multi-function pulse monitor | Factory setting: output frequency (H6-06=2) | 0 to 32 kHz (2.2 k£2) | |
RS-485/422 | R+ | MEMOBUS communications input | For 2-wire RS-485, short R+ and S+ as well as R- and S-. | Differential input, photocoupler isolation |
R- | ||||
S+ | MEMOBUS communications output | Differential input, photocoupler isolation | ||
S- | ||||
IG | Signal common | - | - |